午夜在线不卡精品国产婷婷_亚洲一级黄色毛片全部_毛片大全**在线_最新av一区二区三区影院_一本大道大色av香蕉网_麻豆国产av尤物网尤物_午夜爱爱免费视频无遮挡_717影院理论午夜论不卞_最近2019年中文字幕完整版免费_一个人的视频www片免费

Welcome to the website of Foshan puliang Electronic Co., Ltd Mobile           中文   EN
Hot Keywords:Pressuresensor Pressure transmitter level sensor Temperature sensor
PT500-706
Model: PT500-706
It adopts precision stable pressure sensitive chip and selective placement technology;
Integrated structure of temperature and pressure, monitoring pressure and temperature at the same time;
Double measurement and double output;
High precision, stable, digital calibration adjustment, amplification integrated circuit;
It can replace foreign products of the same type;

Common keywords:
Integrated temperature and pressure transmitter
Integrated pressure and temperature transducer
<
>
  • Product parameters
  • Specification parameter
  • Ordering considerations
  • Precautions for use
  • Common problem
  • Proposal

PT500-706


Model: PT500-706
It adopts precision stable pressure sensitive chip and selective placement technology;
Integrated structure of temperature and pressure, monitoring pressure and temperature at the same time;
Double measurement and double output;
High precision, stable, digital calibration adjustment, amplification integrated circuit;
It can replace foreign products of the same type;

Common keywords:
Integrated temperature and pressure transmitter
Integrated pressure and temperature transducer


Chip:
It adopts precision stable pressure sensitive chip and selective placement technology;
PT100 high precision temperature sensor;
Zero point, fullness, temperature compensation and linear compensation;
High impedance, high precision and high stability;
More than 1 million times of service life;

Signal processing and output:
24 bit ADC sampling and processing chip;
DSP digital signal conditioning algorithm;
Multipoint linear temperature calibration;
Voltage and current overload protection;
Standard industrial signal output: 4-20mA (two-wire system), 0-20mA (three wire system), 0-5vdc, 0-10vdc, 0.5-4.5vdc (three wire system);

Rsu-485, ultra low power consumption of rtu-485 communication
Advanced 32 bit microprocessor and 24 bit ADC are adopted
The transmission protocol is MODBUS-RTU
Support baud rate: 1200 ~ 57600bps, check bits: none, odd, even
Support the user's secondary calibration, reset, anti reset, restore factory operations
Support 11 kinds of units switching, support floating point, integer, percentage, formatted output
The acquisition interval of 0 ~ 43200 seconds (12 hours) can be set, which can not only meet the needs of high-speed acquisition, but also trigger acquisition once to minimize power consumption
Digital communication signal output: CAN2.0B
Measurement rate: 10... 1000Hz can be set, the default is 50 Hz

CANopen output built-in complete CANopen protocol stack, in line with ds301, ds404 specifications, support LSS services, support bootloader online upgrade;
Support baud rate (kbps) 20 / 50 / 100 / 125 / 250 (default) / 500 / 800 / 1000; support features of NMT / heartbeat / SDO / PDO / LSS / bootloader; CANopen protocol stack can be customized according to user requirements;

J1939 output has built-in J1939 protocol stack. PGN, SPN and name can be configured freely, and bootloader online upgrade is supported;
Support baud rate (kbps) 20 / 50 / 100 / 125 / 250 (default) / 500 / 800 / 1000; 
support free configuration of features such as PGN, SPN and name
The J1939 protocol stack can be customized according to the user's requirements;

Structure:
Thick film structure: deep argon arc welding, connecting elastic material and process joint, high strength, impact resistance and fatigue resistance;
PU film structure: laser welding, connecting elastic material and process joint, transmitting pressure with silicone oil medium, fast response, fatigue resistance, small range;
Integrated structure of temperature and pressure, monitoring pressure and temperature at the same time;
The overall structure is compact, and the process connection mode is diversified (m20x1.5, G1 / 2, ZG1 / 2, 1 / 2NPT (thread diameter ≥ 17mm) DN50, etc.);
Process connection material: 304 or 316;

Application:
Pressure measurement and monitoring of power station, oil plant, chemical industry, etc;
Pressure measurement of equipment with flameproof requirements for products in automation and other fields;
Application fields:
  • Fire fighting system

  • Air compressor unit

  • Gas supply system

  • Gas supply pipeline

  • Water supply equipment

  • Hydraulic equipment

Measuring medium: liquid, gas, steam, etc
Pressure form: gauge pressure, absolute pressure
Range:
0~0.6、1、2、5、10、15、20、25、30、40、50、60、100(MPa);
0~100、150、200、250、300、350、400、450、500(MPa)
0~10、20、30、50、100、150、200、300、400、500、600(KPa);
-100KPa~10KPa~40MPa;
±10KPa~±100KPa;
Comprehensive accuracy: ± 0.25% FS; ± 0.5% FS; ± 1% FS
Nonlinearity: ≤ 0.25% FS
Repeatability: ≤ 0.15% FS
Pressure output signal:
Current type: 4-20mA two-wire system; 4-20mA / 0-20mA three-wire system
Voltage type: 0 ~ 5VDC, 0 ~ 10VDC, 0.5 ~ 4.5vdc three wire system
Digital type: rs485-rtu, low power rs485-rtu
CAN2.0B (supports CANopen, J1939 Protocol)
Temperature output signal: PT100 resistance signal
Supply voltage:
24 VDC (9 ~ 30 VDC) universal type
3.1 ~ 6.1vdc (low power rs485-rtu)
5VDC (0.5 ~ 4.5vdc output type)
Service life: ≥ 1 million times
Insulation impedance: ≥ 1000 m Ω / 100VDC
Load impedance: current output: ≤ 800 Ω; voltage output: ≥ 50K Ω
Medium temperature: - 20 ~ 80 ℃
Ambient temperature: - 20 ~ 70 ℃
Compensation temperature: 0 ~ 70 ℃
Response time: ≤ 5ms
Overload pressure: 150% FS
Failure pressure: 3 times of measuring range (less than 40MPa); 2 times of measuring range (measuring range greater than 41mpa)
Electrical connection: Waterproof tight wire nut directly leads out, can be matched with explosion-proof electrical connection
Protection grade: IP67 / IP68
Connecting cable: four core shielded cable, standard length: 3M
Connection material: 304 / 316L
Process connection: m20x1.5, G1 / 2, ZG1 / 2, 1 / 2NPT, DN50 Specification can be made by users











PT500-706
Precautions for ordering PT500-706 products
1. Product range selection:
In order to achieve the best effect of product accuracy, life, stability and other functions, the range selection of the product is calculated by referring to the following formula:
Range = x (1.2-1.5) times of the maximum system pressure;
The actual measuring pressure range of the product should be 15% - 80% of the range;

2. Product power supply and output:
The selection of power supply range is determined according to the output specifications of the product:
Conventional 4-20mA / 0-20mA, 0-5V / 10V output, DC 12-30vdc power supply;
General rs485-rtu output, DC 12-30vdc power supply;
0.5-4.5vdc output, DC 5VDC;
Low power output power supply range: 3.6vdc (3-5vdc)

3. The user should understand the measurement medium characteristics of the product:
Medium specification, medium temperature, medium purity (whether containing impurities or particles, etc.);

4. Users should understand the installation environment and installation method of the product:
Whether the flameproof protection level can meet the requirements of field conditions;
Indoor or outdoor installation;
Ambient temperature;
Required sealing level;
Vibration range of equipment;
Installation method: thread, flange, special structure;
Whether the installation space meets the overall dimension of the product;


Different product signal output specifications correspond to different power supply range requirements;
It is strictly prohibited to use hard objects (such as screwdriver, finger, iron nail, etc.) to make the pressure diaphragm output under pressure measurement;
The power and signal wires shall be correctly wired according to the specifications of the ordered products;
During product installation, the stressed part is "process connection hexagon wrench position", and the wrench specification corresponds to hexagon;
It is strictly prohibited that the medium temperature, pressure range and excitation voltage of the tested system exceed the rated use range of the transmitter;
Pay attention to protect the outgoing cable of the transmitter. When the span is too large on site, it is recommended to use metal pipe for protection or overhead;
The pressure transmitter is a precision measuring instrument. Do not impose impact or smash to avoid damaging the core
The product is installed in a ventilated, dry and non corrosive environment, and installed in the open with protective devices to avoid direct sunlight;
It is strictly prohibited to enter / leak / soak water in the product instrument, and protective devices shall be installed in the open to avoid direct sunlight;

Name
Tel
QQ
WeChat
Mailbox
Address
Content